Operator10 meter formulas: usage, rollovers, and units

Convert totalizer readings to daily usage, set an offset to write to yesterday, handle rollovers automatically, and convert to the units you track—all with Operator10 meter formulas.
Operator10 meter formulas

Operator10 meter formulas change the game. Totalizer readings are great—until the meter rolls over or gets refilled. Operator10 provides a meter-to-usage function designed for this exact scenario so you can calculate daily flow, runtime, or consumption cleanly.

Convert totalizer to daily usage

Use the built-for-purpose meter function to turn today’s and yesterday’s totalizer readings into a daily value. You can set an offset so the calculated usage is written to yesterday (today – yesterday → write to yesterday), which is often what you want for daily sheets.

Handle rollovers automatically

Provide the maximum meter reading once. If the totalizer wraps, Operator10 applies the rollover logic internally, so you still get the correct usage. For tanks or counters that count down, a negative maximum lets you calculate usage the same way after refills.

Convert to the units you track

Add a multiplier/divisor in the meter function to convert raw usage into your working unit (for example, converting to MGD for daily flow). One place to set it—consistent results across the month.

Test your setup

Pick a test date, preview the result, and—if needed—use sample numbers to confirm the conversion. Once it’s right, attach the formula to the parameter that will store usage, not the totalizer itself.

Tips that save time

  • Use clear parameter names like “Flow MGD (Daily)” for results
  • Keep meter formulas above dependent formulas in calculation order
  • Avoid special characters in formula names; use plain text labels

Next step: Check out Operator10 Water → or Operator10 Wastewater →